Normal working conditions and installation conditions |
1. Self-cooling and air-cooled ambient temperature -40 °C ~ 40 °C, |
water-cooled ambient temperature 5 °C ~ 40 °C |
2. Relative humidity of air ≤ 85% |
3. No corrosive gases in the air and dust that destroys insulation |
4. Air pressure 85Kpa-106Kpa |
5. No severe vibration and shock |
6. If there are special occasions, the corresponding experiment should be carried out to prove that the work is reliable. |
7. Forced air cooling: wind speed ≥6m/s, air temperature ≤40°C |
8. Water cooling: flow rate ≥ 4L / min, water pressure: 0.2 ± 0.03Mpa, water resistivity ≥ 20kΩ |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP400A/1600V | 400 | 100 | 4400 | 9.70E+04 | 1.35 | 900 | 175 | 0.0800 | 0.0200 |
ZP800A/1600V | 800 | 100 | 8800 | 3.80E+05 | 1.30 | 1500 | 175 | 0.0540 | 0.0100 |
ZP1300A/1600V | 1300 | 100 | 14300 | 1.00E+06 | 1.25 | 1500 | 175 | 0.0390 | 0.0080 |
ZP2500A/1600V | 2500 | 100 | 27500 | 3.80E+06 | 1.35 | 3000 | 175 | 0.0220 | 0.0050 |
ZP3200A/1600V | 3200 | 100 | 35200 | 6.00E+06 | 1.30 | 3000 | 175 | 0.0150 | 0.0045 |
ZP4600A/1600V | 4600 | 90 | 50600 | 1.30E+07 | 1.15 | 3000 | 175 | 0.0125 | 0.0040 |
ZP6000A/1600V | 6000 | 90 | 66000 | 2.10E+07 | 1.15 | 3000 | 175 | 0.0100 | 0.0030 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP300A/2400V | 300 | 100 | 3600 | 6.50E+04 | 1.40 | 900 | 175 | 0.0800 | 0.0200 |
ZP600A/2400V | 600 | 100 | 7200 | 2.60E+05 | 1.40 | 1500 | 175 | 0.0540 | 0.0100 |
ZP1100A/2400V | 1100 | 100 | 13200 | 8.70E+05 | 1.30 | 1500 | 175 | 0.0390 | 0.0080 |
ZP2000A/2400V | 2000 | 100 | 24000 | 2.90E+06 | 1.45 | 3000 | 175 | 0.0220 | 0.0050 |
ZP2500A/2400V | 2500 | 100 | 30000 | 4.50E+06 | 1.40 | 3000 | 175 | 0.0150 | 0.0045 |
ZP34000A/2400V | 3400 | 100 | 40800 | 8.30E+06 | 1.25 | 3000 | 175 | 0.0125 | 0.0040 |
ZP4400A/2400V | 4400 | 100 | 52800 | 1.40E+07 | 1.20 | 3000 | 175 | 0.0100 | 0.0030 |
ZP6500A/2400V | 6500 | 90 | 78000 | 3.00E+07 | 1.25 | 5000 | 175 | 0.0080 | 0.0020 |
ZP7500A/2400V | 7500 | 100 | 90000 | 4.00E+07 | 1.15 | 3000 | 175 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP200A/3500V | 200 | 100 | 2800 | 4.00E+04 | 1.55 | 600 | 150 | 0.0800 | 0.0200 |
ZP700A/3500V | 700 | 100 | 9800 | 4.80E+05 | 1.95 | 1500 | 175 | 0.0540 | 0.0100 |
ZP800A/3500V | 800 | 90 | 11200 | 6.20E+05 | 1.70 | 1500 | 150 | 0.0390 | 0.0080 |
ZP1350A/3500V | 1350 | 90 | 18900 | 1.70E+06 | 1.60 | 3000 | 150 | 0.0220 | 0.0050 |
ZP2000A/3500V | 2000 | 90 | 28000 | 4.00E+06 | 1.55 | 3000 | 150 | 0.0150 | 0.0045 |
ZP2900A/3500V | 2900 | 90 | 40600 | 8.00E+06 | 1.50 | 3000 | 160 | 0.0125 | 0.0040 |
ZP3500A/3500V | 3500 | 90 | 49000 | 1.20E+07 | 1.35 | 3000 | 160 | 0.0100 | 0.0030 |
ZP5000A/3500V | 5000 | 100 | 70000 | 2.40E+07 | 1.35 | 5000 | 175 | 0.0080 | 0.0020 |
ZP5800A/2400V | 5800 | 90 | 81200 | 3.30E+07 | 1.20 | 5000 | 160 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP500A/4500V | 500 | 100 | 7500 | 2.80E+05 | 2.10 | 1500 | 150 | 0.0540 | 0.0100 |
ZP640A/4500V | 600 | 100 | 9600 | 4.60E+05 | 1.90 | 1500 | 150 | 0.0390 | 0.0080 |
ZP1200A/4500V | 1200 | 100 | 18000 | 1.60E+06 | 2.00 | 3000 | 150 | 0.0220 | 0.0050 |
ZP1350A/4500V | 1350 | 100 | 20250 | 2.00E+06 | 1.80 | 3000 | 150 | 0.0150 | 0.0045 |
ZP1900A/4500V | 1900 | 100 | 28500 | 4.00E+06 | 1.70 | 3000 | 150 | 0.0125 | 0.0040 |
ZP2500A/4500V | 2500 | 100 | 37500 | 7.00E+06 | 1.60 | 3000 | 150 | 0.0100 | 0.0030 |
ZP4000A/4500V | 4000 | 100 | 60000 | 1.80E+07 | 1.45 | 5000 | 160 | 0.0080 | 0.0020 |
ZP5200A/4500V | 5200 | 90 | 78000 | 3.00E+07 | 1.35 | 5000 | 150 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP2100A/5200V | 2100 | 100 | 31500 | 5.00E+06 | 1.50 | 3000 | 150 | 0.0100 | 0.0030 |
ZP3400A/5200V | 3400 | 90 | 51000 | 1.30E+07 | 1.35 | 5000 | 150 | 0.0080 | 0.0020 |
ZP2400A/6500V | 2400 | 100 | 36000 | 6.50E+06 | 1.50 | 5000 | 150 | 0.0080 | 0.0020 |
ZP3500A/6500V | 3500 | 100 | 52500 | 1.40E+07 | 1.45 | 5000 | 150 | 0.0060 | 0.0015 |
ZP500A/7200V | 500 | 100 | 7500 | 2.80E+05 | 2.00 | 1500 | 150 | 0.0390 | 0.0080 |
ZP960A/9200V | 960 | 100 | 14400 | 1.00E+06 | 1.75 | 1500 | 150 | 0.0220 | 0.0050 |
please click here to submit your inquiry details!
Application
The Thyristor Power Regulator, commonly known as the SCR power controller, is expertly designed to manage power delivery and is widely utilized in:
1. Aluminium melting furnaces;
2. Holding furnaces;
3. Boilers;
4. Microwave dryers;
5. Multi-zone drying and curing ovens;
6. Plastic injection moulding requiring multi-zone heating for manifold moulds;
7. Plastic pipes and sheets extrusion;
8. Metal sheets welding systems;
please click here to submit your inquiry details!
OUR REQUIREMENT
please click here to submit your inquiry details!
FAQ