Normal Working and Installation Conditions
1. The cooling methods include self-cooling and air-cooling, efficient in ambient temperatures ranging from -40°C to 40°C, ensuring consistent performance.
2. Water-cooled systems are optimized for ambient temperatures between 5°C and 40°C, maintaining reliability.
3. Relative humidity of the air should be ≤ 85% to ensure optimal functioning and longevity.
4. The environment must be free from corrosive gases and insulating-destructive dust particles.
5. Maintain air pressure levels between 85Kpa and 106Kpa for effective operation.
6. The installation site must be devoid of severe vibration and shock to ensure stability.
7. For special circumstances, a comprehensive experiment is necessary to validate operational reliability.
8. Forced air cooling requires a wind speed of ≥6m/s and an air temperature of ≤40°C, ensuring efficient cooling.
9. Water cooling demands a flow rate of ≥4L/min, water pressure of 0.2 ± 0.03Mpa, and water resistivity of ≥20kΩ for superior efficiency.
| Product name | Factory direct sale cathode anode scr stud type rectifier diode |
| Rated Current | 400-5800A |
| Temperature | Below 40°C |
| Operation Frequency | 50Hz/60Hz |
| Color | Red |
| Service | 24 hours service |
| OEM and ODM | Acceptable |
| Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
| A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
| ZP400A/1600V | 400 | 100 | 4400 | 9.70E+04 | 1.35 | 900 | 175 | 0.0800 | 0.0200 |
| ZP800A/1600V | 800 | 100 | 8800 | 3.80E+05 | 1.30 | 1500 | 175 | 0.0540 | 0.0100 |
| ZP1300A/1600V | 1300 | 100 | 14300 | 1.00E+06 | 1.25 | 1500 | 175 | 0.0390 | 0.0080 |
| ZP2500A/1600V | 2500 | 100 | 27500 | 3.80E+06 | 1.35 | 3000 | 175 | 0.0220 | 0.0050 |
| ZP3200A/1600V | 3200 | 100 | 35200 | 6.00E+06 | 1.30 | 3000 | 175 | 0.0150 | 0.0045 |
| ZP4600A/1600V | 4600 | 90 | 50600 | 1.30E+07 | 1.15 | 3000 | 175 | 0.0125 | 0.0040 |
| ZP6000A/1600V | 6000 | 90 | 66000 | 2.10E+07 | 1.15 | 3000 | 175 | 0.0100 | 0.0030 |
| Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
| A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
| ZP300A/2400V | 300 | 100 | 3600 | 6.50E+04 | 1.40 | 900 | 175 | 0.0800 | 0.0200 |
| ZP600A/2400V | 600 | 100 | 7200 | 2.60E+05 | 1.40 | 1500 | 175 | 0.0540 | 0.0100 |
| ZP1100A/2400V | 1100 | 100 | 13200 | 8.70E+05 | 1.30 | 1500 | 175 | 0.0390 | 0.0080 |
| ZP2000A/2400V | 2000 | 100 | 24000 | 2.90E+06 | 1.45 | 3000 | 175 | 0.0220 | 0.0050 |
| ZP2500A/2400V | 2500 | 100 | 30000 | 4.50E+06 | 1.40 | 3000 | 175 | 0.0150 | 0.0045 |
| ZP34000A/2400V | 3400 | 100 | 40800 | 8.30E+06 | 1.25 | 3000 | 175 | 0.0125 | 0.0040 |
| ZP4400A/2400V | 4400 | 100 | 52800 | 1.40E+07 | 1.20 | 3000 | 175 | 0.0100 | 0.0030 |
| ZP6500A/2400V | 6500 | 90 | 78000 | 3.00E+07 | 1.25 | 5000 | 175 | 0.0080 | 0.0020 |
| ZP7500A/2400V | 7500 | 100 | 90000 | 4.00E+07 | 1.15 | 3000 | 175 | 0.0060 | 0.0015 |
| Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
| A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
| ZP200A/3500V | 200 | 100 | 2800 | 4.00E+04 | 1.55 | 600 | 150 | 0.0800 | 0.0200 |
| ZP700A/3500V | 700 | 100 | 9800 | 4.80E+05 | 1.95 | 1500 | 175 | 0.0540 | 0.0100 |
| ZP800A/3500V | 800 | 90 | 11200 | 6.20E+05 | 1.70 | 1500 | 150 | 0.0390 | 0.0080 |
| ZP1350A/3500V | 1350 | 90 | 18900 | 1.70E+06 | 1.60 | 3000 | 150 | 0.0220 | 0.0050 |
| ZP2000A/3500V | 2000 | 90 | 28000 | 4.00E+06 | 1.55 | 3000 | 150 | 0.0150 | 0.0045 |
| ZP2900A/3500V | 2900 | 90 | 40600 | 8.00E+06 | 1.50 | 3000 | 160 | 0.0125 | 0.0040 |
| ZP3500A/3500V | 3500 | 90 | 49000 | 1.20E+07 | 1.35 | 3000 | 160 | 0.0100 | 0.0030 |
| ZP5000A/3500V | 5000 | 100 | 70000 | 2.40E+07 | 1.35 | 5000 | 175 | 0.0080 | 0.0020 |
| ZP5800A/2400V | 5800 | 90 | 81200 | 3.30E+07 | 1.20 | 5000 | 160 | 0.0060 | 0.0015 |
| Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
| A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
| ZP500A/4500V | 500 | 100 | 7500 | 2.80E+05 | 2.10 | 1500 | 150 | 0.0540 | 0.0100 |
| ZP640A/4500V | 600 | 100 | 9600 | 4.60E+05 | 1.90 | 1500 | 150 | 0.0390 | 0.0080 |
| ZP1200A/4500V | 1200 | 100 | 18000 | 1.60E+06 | 2.00 | 3000 | 150 | 0.0220 | 0.0050 |
| ZP1350A/4500V | 1350 | 100 | 20250 | 2.00E+06 | 1.80 | 3000 | 150 | 0.0150 | 0.0045 |
| ZP1900A/4500V | 1900 | 100 | 28500 | 4.00E+06 | 1.70 | 3000 | 150 | 0.0125 | 0.0040 |
| ZP2500A/4500V | 2500 | 100 | 37500 | 7.00E+06 | 1.60 | 3000 | 150 | 0.0100 | 0.0030 |
| ZP4000A/4500V | 4000 | 100 | 60000 | 1.80E+07 | 1.45 | 5000 | 160 | 0.0080 | 0.0020 |
| ZP5200A/4500V | 5200 | 90 | 78000 | 3.00E+07 | 1.35 | 5000 | 150 | 0.0060 | 0.0015 |
| Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
| A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
| ZP2100A/5200V | 2100 | 100 | 31500 | 5.00E+06 | 1.50 | 3000 | 150 | 0.0100 | 0.0030 |
| ZP3400A/5200V | 3400 | 90 | 51000 | 1.30E+07 | 1.35 | 5000 | 150 | 0.0080 | 0.0020 |
| ZP2400A/6500V | 2400 | 100 | 36000 | 6.50E+06 | 1.50 | 5000 | 150 | 0.0080 | 0.0020 |
| ZP3500A/6500V | 3500 | 100 | 52500 | 1.40E+07 | 1.45 | 5000 | 150 | 0.0060 | 0.0015 |
| ZP500A/7200V | 500 | 100 | 7500 | 2.80E+05 | 2.00 | 1500 | 150 | 0.0390 | 0.0080 |
| ZP960A/9200V | 960 | 100 | 14400 | 1.00E+06 | 1.75 | 1500 | 150 | 0.0220 | 0.0050 |
For more information, please click here to submit your inquiry details!
Feel free to submit your inquiry details by clicking here!
Submit your inquiry details by clicking here for more information!
Application
The Thyristor Power Regulator, or SCR power controller, is meticulously engineered for power management, finding extensive applications in:
1. Aluminium melting furnaces, offering precision and efficiency.
2. Holding furnaces, ensuring consistent temperature maintenance.
3. Boilers, providing reliable power management.
4. Microwave dryers, delivering uniform drying solutions.
5. Multi-zone drying and curing ovens, ensuring precise temperature control.
6. Plastic injection moulding with multi-zone heating, optimal for manifold moulds.
7. Plastic pipes and sheets extrusion, catering to diverse production needs.
8. Metal sheets welding systems, supporting seamless operations.

please click here to submit your inquiry details!
OUR REQUIREMENT


For certification details, please click here to submit your inquiry!

FAQ