Normal working conditions and installation conditions
1. The product operates efficiently in self-cooling and air-cooled environments with ambient temperatures ranging from -40 °C to 40 °C, ensuring reliability across diverse climatic conditions.
Water-cooled systems are optimal in ambient temperatures between 5 °C and 40 °C, delivering consistent performance.
2. Designed to function seamlessly with a relative humidity of air ≤ 85%, maintaining performance integrity.
3. The air quality is maintained free of corrosive gases and dust that could compromise insulation, ensuring durability.
4. Operates under stable air pressures of 85Kpa-106Kpa, adapting to varying atmospheric conditions.
5. Built to withstand environments free from severe vibrations and shocks, promoting longevity.
6. For unique or challenging environments, tailored experiments can be conducted to verify and guarantee reliable operation.
7. Enhanced forced air cooling is achieved with a wind speed of ≥6m/s and an air temperature of ≤40°C, optimizing heat dissipation.
8. Water cooling systems require a flow rate of ≥ 4L / min, water pressure at 0.2 ± 0.03Mpa, with water resistivity ≥ 20kΩ to ensure efficient thermal management.
Product name | Factory direct sale cathode anode scr stud type rectifier diode |
Rated Current | 400-5800A |
Temperature | Below 40°C |
Operation Frequency | 50Hz/60Hz |
Color | Red |
Service | 24 hours service |
OEM and ODM | Acceptable |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP400A/1600V | 400 | 100 | 4400 | 9.70E+04 | 1.35 | 900 | 175 | 0.0800 | 0.0200 |
ZP800A/1600V | 800 | 100 | 8800 | 3.80E+05 | 1.30 | 1500 | 175 | 0.0540 | 0.0100 |
ZP1300A/1600V | 1300 | 100 | 14300 | 1.00E+06 | 1.25 | 1500 | 175 | 0.0390 | 0.0080 |
ZP2500A/1600V | 2500 | 100 | 27500 | 3.80E+06 | 1.35 | 3000 | 175 | 0.0220 | 0.0050 |
ZP3200A/1600V | 3200 | 100 | 35200 | 6.00E+06 | 1.30 | 3000 | 175 | 0.0150 | 0.0045 |
ZP4600A/1600V | 4600 | 90 | 50600 | 1.30E+07 | 1.15 | 3000 | 175 | 0.0125 | 0.0040 |
ZP6000A/1600V | 6000 | 90 | 66000 | 2.10E+07 | 1.15 | 3000 | 175 | 0.0100 | 0.0030 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP300A/2400V | 300 | 100 | 3600 | 6.50E+04 | 1.40 | 900 | 175 | 0.0800 | 0.0200 |
ZP600A/2400V | 600 | 100 | 7200 | 2.60E+05 | 1.40 | 1500 | 175 | 0.0540 | 0.0100 |
ZP1100A/2400V | 1100 | 100 | 13200 | 8.70E+05 | 1.30 | 1500 | 175 | 0.0390 | 0.0080 |
ZP2000A/2400V | 2000 | 100 | 24000 | 2.90E+06 | 1.45 | 3000 | 175 | 0.0220 | 0.0050 |
ZP2500A/2400V | 2500 | 100 | 30000 | 4.50E+06 | 1.40 | 3000 | 175 | 0.0150 | 0.0045 |
ZP34000A/2400V | 3400 | 100 | 40800 | 8.30E+06 | 1.25 | 3000 | 175 | 0.0125 | 0.0040 |
ZP4400A/2400V | 4400 | 100 | 52800 | 1.40E+07 | 1.20 | 3000 | 175 | 0.0100 | 0.0030 |
ZP6500A/2400V | 6500 | 90 | 78000 | 3.00E+07 | 1.25 | 5000 | 175 | 0.0080 | 0.0020 |
ZP7500A/2400V | 7500 | 100 | 90000 | 4.00E+07 | 1.15 | 3000 | 175 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP200A/3500V | 200 | 100 | 2800 | 4.00E+04 | 1.55 | 600 | 150 | 0.0800 | 0.0200 |
ZP700A/3500V | 700 | 100 | 9800 | 4.80E+05 | 1.95 | 1500 | 175 | 0.0540 | 0.0100 |
ZP800A/3500V | 800 | 90 | 11200 | 6.20E+05 | 1.70 | 1500 | 150 | 0.0390 | 0.0080 |
ZP1350A/3500V | 1350 | 90 | 18900 | 1.70E+06 | 1.60 | 3000 | 150 | 0.0220 | 0.0050 |
ZP2000A/3500V | 2000 | 90 | 28000 | 4.00E+06 | 1.55 | 3000 | 150 | 0.0150 | 0.0045 |
ZP2900A/3500V | 2900 | 90 | 40600 | 8.00E+06 | 1.50 | 3000 | 160 | 0.0125 | 0.0040 |
ZP3500A/3500V | 3500 | 90 | 49000 | 1.20E+07 | 1.35 | 3000 | 160 | 0.0100 | 0.0030 |
ZP5000A/3500V | 5000 | 100 | 70000 | 2.40E+07 | 1.35 | 5000 | 175 | 0.0080 | 0.0020 |
ZP5800A/2400V | 5800 | 90 | 81200 | 3.30E+07 | 1.20 | 5000 | 160 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP500A/4500V | 500 | 100 | 7500 | 2.80E+05 | 2.10 | 1500 | 150 | 0.0540 | 0.0100 |
ZP640A/4500V | 600 | 100 | 9600 | 4.60E+05 | 1.90 | 1500 | 150 | 0.0390 | 0.0080 |
ZP1200A/4500V | 1200 | 100 | 18000 | 1.60E+06 | 2.00 | 3000 | 150 | 0.0220 | 0.0050 |
ZP1350A/4500V | 1350 | 100 | 20250 | 2.00E+06 | 1.80 | 3000 | 150 | 0.0150 | 0.0045 |
ZP1900A/4500V | 1900 | 100 | 28500 | 4.00E+06 | 1.70 | 3000 | 150 | 0.0125 | 0.0040 |
ZP2500A/4500V | 2500 | 100 | 37500 | 7.00E+06 | 1.60 | 3000 | 150 | 0.0100 | 0.0030 |
ZP4000A/4500V | 4000 | 100 | 60000 | 1.80E+07 | 1.45 | 5000 | 160 | 0.0080 | 0.0020 |
ZP5200A/4500V | 5200 | 90 | 78000 | 3.00E+07 | 1.35 | 5000 | 150 | 0.0060 | 0.0015 |
Type | If(AV) | TC | Itsm@Tvjim&10ms | I2t | Vtm@It&Tj=25ºC | Itm@It&Tj=25ºC | Tjm | Rjc | Rc-s |
A | ºC | A | A2s | V | A | ºC | ºC/W | ºC/W | |
ZP2100A/5200V | 2100 | 100 | 31500 | 5.00E+06 | 1.50 | 3000 | 150 | 0.0100 | 0.0030 |
ZP3400A/5200V | 3400 | 90 | 51000 | 1.30E+07 | 1.35 | 5000 | 150 | 0.0080 | 0.0020 |
ZP2400A/6500V | 2400 | 100 | 36000 | 6.50E+06 | 1.50 | 5000 | 150 | 0.0080 | 0.0020 |
ZP3500A/6500V | 3500 | 100 | 52500 | 1.40E+07 | 1.45 | 5000 | 150 | 0.0060 | 0.0015 |
ZP500A/7200V | 500 | 100 | 7500 | 2.80E+05 | 2.00 | 1500 | 150 | 0.0390 | 0.0080 |
ZP960A/9200V | 960 | 100 | 14400 | 1.00E+06 | 1.75 | 1500 | 150 | 0.0220 | 0.0050 |
For further information or to submit your inquiry details, please click here!
For further information or to submit your inquiry details, please click here!
Application
The Thyristor Power Regulator, or SCR power controller, is expertly engineered for precise power management and is extensively applied in:
1. Aluminium melting furnaces, offering optimal energy control;
2. Holding furnaces, enhancing thermal stability;
3. Boilers, maximizing heating efficiency;
4. Microwave dryers, ensuring uniform drying processes;
5. Multi-zone drying and curing ovens, facilitating flexible temperature control;
6. Plastic injection moulding with multi-zone heating, ideal for manifold moulds;
7. Plastic pipes and sheets extrusion, providing precise thermal regulation;
8. Metal sheets welding systems, ensuring consistent welding quality.
For further information or to submit your inquiry details, please click here!
OUR REQUIREMENT
For further information or to submit your inquiry details, please click here!
FAQ